  "date": "2026-09-20",
  "reviewer_source_sha256": "9ec31b3d8316d7cd99f90894bd81d1b8fd4a4be5a956c3ffaf1cb09d2085927c",
  "scope": "Readback independent Kirchhoff laws, segment lengths, cut modules, counts and source budgets. No physical electrical or tent qualification.",
  "revisions": [
    {
      "revision": "r7",
      "input_sha256": {
        "build/lighting_stage5/r7/electrical.json": "c4110e47cdb4e00a3e332d40d655b12121d61f0613321b90e59ff2a9dc15530b",
        "build/lighting_stage5/r7/finishings.json": "5b66fab9b1d0954829c971e8b953acdcc5849444c41f03cd40b911901775b617",
        "build/lighting_stage5/r7/geometry_audit.json": "877148d2e51b9faf8a49c9b94baa5ac2182cc465cf8b2c3f67073d625764719f"
      },
      "arithmetic_pass": true,
      "freshness_pass": true,
      "geometry_audit_readback_only": {
        "collision_free": true,
        "checked_pairs": 556,
        "scope": "Actual LED, clips and endcap envelopes versus all actual assembly STL, including hardware; cable bends and pilot drilling excluded."
      },
      "power_supplies_per_assembly": 1,
      "dimmers_per_assembly": 1,
      "branch_count": 52,
      "led_length_m": 19.8,
      "led_power_nominal_upper_w": 209.88000000000002,
      "current_a": 8.745000000000001,
      "maximum_wiring_drop_v": 0.1470662282746009,
      "trunk_copper_loss_w": 1.0235902061074302,
      "tails_copper_loss_w": 0.027792421562500023,
      "source_VI_upper_w_at_model_current": 215.309551875,
      "terminal_bounds_v": [
        23.132058771725404,
        24.620874999999998
      ],
      "minimum_voltage_margin_v": 0.13205877172540426,
      "other_loss_budget_maximum_series_resistance_ohm": 0.022870211549456832,
      "external_6mm2_oneway_length_if_all_other_budget_used_by_cable_m": 3.2671730784938333,
      "dimmer_15A_margin_a": 6.254999999999999,
      "source_power_w": 320.16,
      "suggested_common_fuse_a_readback": 15,
      "maximum_readback_error": 1.4210854715202004e-13,
      "construction_ready": false,
      "physical_wiring_and_cover_clearance_verified": false,
      "capacity_conditional_on_10_6W_per_m_upper_load": true
    },
    {
      "revision": "r8",
      "input_sha256": {
        "build/lighting_stage5/r8/electrical.json": "b28739450b32cccd956ae657898d8818169a1511f187412a95b5ea4f438faf04",
        "build/lighting_stage5/r8/finishings.json": "991825b8f07b5fddf565149755f32f2c36b0e511de7ad1f64a513e18ecbe08db",
        "build/lighting_stage5/r8/geometry_audit.json": "f9681aeff3a41676d8cf1bec3b68c4823607b44e72ffe632831dd0037e1302de"
      },
      "arithmetic_pass": true,
      "freshness_pass": true,
      "geometry_audit_readback_only": {
        "collision_free": true,
        "checked_pairs": 632,
        "scope": "Actual LED, clips and endcap envelopes versus all actual assembly STL, including hardware; cable bends and pilot drilling excluded."
      },
      "power_supplies_per_assembly": 1,
      "dimmers_per_assembly": 1,
      "branch_count": 20,
      "led_length_m": 31.4,
      "led_power_nominal_upper_w": 332.84,
      "current_a": 13.868333333333332,
      "maximum_wiring_drop_v": 0.2254050996478511,
      "trunk_copper_loss_w": 2.381950190128318,
      "tails_copper_loss_w": 0.40005807260416665,
      "source_VI_upper_w_at_model_current": 341.3100845833333,
      "terminal_bounds_v": [
        23.06384490035215,
        24.61075
      ],
      "minimum_voltage_margin_v": 0.06384490035215151,
      "other_loss_budget_maximum_series_resistance_ohm": 0.014421343588510998,
      "external_6mm2_oneway_length_if_all_other_budget_used_by_cable_m": 2.060191941215857,
      "dimmer_15A_margin_a": 1.1316666666666677,
      "source_power_w": 480.0,
      "suggested_common_fuse_a_readback": 20,
      "maximum_readback_error": 5.684341886080802e-14,
      "construction_ready": false,
      "physical_wiring_and_cover_clearance_verified": false,
      "capacity_conditional_on_10_6W_per_m_upper_load": true
    }
  ]
}